| Features of SCENAR 1-NT 02.3 |
Descriptions |
Purposes of applying |
| 2 General Modes of applying |
1. Subjective Dosed Mode (subjective diagnostic and therapy mode). This mode turned on when "Diag off" indicated on the screen.
2. Individual Dosed Mode (digital diagnostic and therapy mode). This mode turns on when "Diag 1" indicates on the screen. |
1. To subjectively find "Asymmetry" points (pathological, deviation areas) in general and then treating them
2. To digitally find "Asymmetry" points (pathological, deviation areas) in general and then treating them |
| Wide range of power |
The device have scale of powers from 1 to 250 with step 1. |
We set comfortable power (energy) level individually at the beginning of the session. For some individuals it can be 10, for others 60 or more. In some cases like emergency conditions or severe pain we need to set high energy level up to 250. |
| Wide range of frequencies |
15-350 Hz |
Low frequencies 15-60 Hz applies for degenerate conditions, high ones (120 and more Hz) - for inflammatory. High frequencies applies for acute pain relief also, low ones - for chronic or uncertain pain or complaint. |
| Frequency Modulation (FM) |
If the frequency modulation turned on, the device generate different frequencies: from 30 Hz to 120 Hz to 30 Hz to 120 Hz etc.
 |
To get the faster and better results on patients, who have uncertain pain or complaint or who can't efficiently respond to fixed frequencies. |
| Amplitude modulation (AM) |
Preset Power Level/Minimal Power Level Ratio by time (in seconds) 5:1, 4:1, 3:1, 2:1 or 1:1.
 |
During acute pathologic process it is recommended to use 3:1 AM Mode and then turn on 1:1 Mode. During chronic process we start from 3:1 AM Mode and then use 5:1. |
| Intensity |
Intensity - number of waveforms within one bundle (bundles per second = Frequency). There are 8 steps of intensity - from 1 to 8
 |
High Intensity (4 and more) can be applied in case of acute inflammation or severe pain. They have a powerful local effect. |
| Damping (waveform modulation) |
Damping - changing form of impulse during treatment. There are 6 Damping variants:
- Damping Sk1
- Damping Sk2
- Damping Sk3
- Damping Sk4
- Damping Var (combination of previous variants)
- Damping Off
 |
|
| Gap variants |
Gap is interval between impulses within bundle. (bundles per second = Frequency). It can be set at 10 - 80 (200 microseconds to 1600 microseconds).
 |
We use high Gap (more than 40) if local signs of the disease predominate over the general ones. If general signs predominate over local ones, we use low Gap (10). |
If you have any questions please contact Vlad Ostro at: SCENAR8@aol.com
Disclaimer: SCENAR and DENAS/DiaDENS have been approved in Europe, Australia and Russia for medical usage. SCENAR registered in FDA as BioFeedBack device, not for medical usage, but for research purposes only. See details here.