SCENAR Theory


SCENAR is acronym for Self Controlled Energetic Neuro Adaptive Regulator. Working on the surface of the skin*, SCENAR finds and then treats pathological skin points, concerned with the disease. We call these skin points "asymmetric points."

The SCENAR device speaks on Human Body's language, producing electric impulses, similar to the natural signals of the cells. That's why it can restore link between regulation center (brain) and the internal organs of the human body. It is well known that pathological conductivity of signals is the main cause of the diseases. Then organism starts to cure itself, because it becomes aware of the disease location.

SCENAR not only assists in the acute phase of the condition, but also helps organism to eliminate chronic processes, achieve balanced state and improves natural capability of the body to resist pathological influences in future.

In general SCENAR is an instrument which does not cure, it just lets the body to detect the problem and to treat this problem. That's why SCENAR is an absolutely safe** device - human body can not hurt itself.

Technical features.

SCENAR device produces pulse bipolar current without constant component.

Form of SCENAR Impulse without load. Form of SCENAR Impulse on-load (the device contact with the skin) Different variants of SCENAR impulses on-load depending on skin resistance. The form and duration of impulse changing all time during the treatment because skin resistance dynamically changing too.
SCENAR Impulse without loading
SCENAR Impulse on load

Different SCENAR Impulses on load

Functions of the SCENAR devices

Functions Descriptions Purposes of applying
2 General Modes of applying 1. Subjective Dosed Mode (subjective diagnostic and therapy mode). This mode turned on when "Diag off" indicated on the screen.
2. Individual Dosed Mode (digital diagnostic and therapy mode). This mode turned on when "Diag 1 or 2" indicated on the screen.

1. To subjectively find "Asymmetry" points (pathological, deviation areas) in general and then treating them

2. To digitally find "Asymmetry" points (pathological, deviation areas) in general and then treating them

Wide range of power The device have scale of powers from 1 to 250 with step 1. We set comfortable power (energy) level individually at the beginning of the session. For some individuals it can be 10, for others 60 or more. In some cases like emergency conditions or severe pain we need to set high energy level up to 250.
Wide range of frequencies 15-350 Hz Low frequencies 15-60 Hz applies for degenerate conditions, high ones (120 and more Hz) - for inflammatory. High frequencies applies for acute pain relief also, low ones - for chronic or uncertain pain or complaint.
Frequency Modulation (FM) If the frequency modulation turned on, the device generate different frequencies: from 30 Hz to 120 Hz to 30 Hz to 120 Hz etc.
To get the faster and better results on patients, who have uncertain pain or complaint or who can't efficiently respond to fixed frequencies.
Amplitude modulation (AM) Preset Power Level/Minimal Power Level Ratio by time (in seconds) 5:1, 4:1, 3:1, 2:1 or 1:1.
During acute pathologic process it is recommended to use 3:1 AM Mode and then turn on 1:1 Mode. During chronic process we start from 3:1 AM Mode and then use 5:1.
Intensity Intensity - number of waveforms within one bundle (bundles per second = Frequency). There are 8 steps of intensity - from 1 to 8
High Intensity (4 and more) can be applied in case of acute inflammation or severe pain. They have a powerful local effect. Low Intensities have general effects.
Damping (waveform modulation) Damping - changing form of impulse during treatment. There are 6 Damping variants:
- Damping Sk1
- Damping Sk2
- Damping Sk3
- Damping Sk4
- Damping Var (combination of previous variants)
- Damping Off
In the acute phase of the disease with evident symptoms we apply Sk2 or Sk3. In the phase of decreasing symptoms it is recommended to apply Sk1 or Damping Off mode.
Gap variants Gap is interval between impulses within bundle. (bundles per second = Frequency). It can be set at 10 - 80 (200 microseconds to 1600 microseconds).
We use high Gap (more than 40) if local signs of the disease predominate over the general ones. If general signs predominate over local ones, we use low Gap (10).
Swing modes (combined modulations).

There are four Swing Modes in SCENAR 1 NT 02.1:
1. Sw1 Mode include frequency modulation "on" + Intensity 3 + variable Gap (10-80) + Damping Var
2. Sw2 Mode include frequency modulation "on" + Intensity 3 + variable Gap (10-25) + Damping Var
3. Sw3 Mode include frequency modulation "on" + Intensity 3 + variable Gap (10-73) + Damping Var
4. Sw4 Mode include frequency modulation "on" + variable Intensity (1-4) + variable Gap (10-80) + Damping Var

We use different types of Swing Modes if we don't have ability or time to select suitable regimens for individual.

* The skin is one of the main informational organs of the body. The skin develops together with the nervous system from the same leaf of the fetus during the very first period of fetal life. Some Russian scientists call skin "peripheral brain".

**The other reason of device safety is its very superficial penetration of impulses - skin penetration is not more than 1 millimeter - it is just informational penetration (see disclaimer).

If you have any questions please contact Vlad Ostro at: SCENAR8@aol.com

Disclaimer: SCENAR and DENAS/DiaDENS have been approved in Europe, Australia and Russia for medical usage. SCENAR registered in FDA as a biofeedack device, not for medical usage, but for research purposes only. See details here.